Case Study: Oxidizer Rebuild
Industry
Service and Maintenance
Problem
Anguil was called in to provide an engineering evaluation of a competitor's RTO that was suffering from visible deterioration and "hot spot" issues. Due to the customer's production schedule, an internal inspection was not possible prior to the plant shutdown for repairs.
Action
Anguil was able to couple knowledge of the customer's process with its RTO experience and provide a plan to repair the damaged parts and to replace the RTO media and insulation.
Solution
Anguil arranged for a Senior Design Engineer to be on site during the project so that each step could be approved instantly. As a result of Anguil's preparation and experience, the installation team was prepared for contingencies and system repairs were completed on time.
- A complete ceramic media replacement was done
- Insulation erosion and "hot spot" issues were addressed and fixed
|